Shop

CellarPro Ducted Air Handler Split 1/3 Ton AH3500Si

$5,295.00

CellarPro AH3500Si Ducted Air Handler Split cooling units (1/3 Ton Nominal) are engineered for wine cellars up to 900* cubic feet in both commercial and residential wine cellars.

SKU: AH3500Si-36244 Category:
CellarPro AH3500Si-ECX Cooling Unit (P/N 36244). CellarPro engineered the AH3500Si-ECX ducted cooling system to provide maximum cooling power and adjustable humidity control for cellars up to 900 cubic feet. The evaporator and the condensing unit each can be ducted up to 100 equivalent feet (50 equivalent feet per duct.) As a split system, the evaporator can be separated from the condensing unit up to 100 feet, allowing the noise and heat from the condensing unit to be located away from interior living areas. Designed for internal installations, the AH3500Si-ECX includes energy-efficient independent variable-speed EC fans with a low setting for quieter operation and a high setting for maximum power.

All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space – it must come from space outside the cellar.


    Overview

    CellarPro’s AH3500Si-ECX ducted cooling units (1/3 Ton Nominal) are engineered for wine cellars up to 900* cubic feet in both commercial and residential wine cellars. This ducted unit uses 8-inch ducting and requires insulated ducting on the cold side.

    This unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110F. AH3500Si units use energy-efficient EC fans and are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.

    For installation of the condensing unit in environments below 20F down to -20F, our Fan Cycling Switch (P/N 6972) is a required addition, and Electronic Configuration is required.

    *Assuming R19 insulation throughout the cellar, 55F inside the cellar and 85F outside the cellar. Cold-side ducting, glass and/or uninsulated walls, extreme humidity, altitude and other factors may affect the sizing calculation.

    Our cooling units are designed to be used in properly-constructed wine cellars that are adequately insulated, airtight and sealed with a vapor barrier. In improperly-constructed cellars, the cooling unit will create excess condensation, leading to damage and premature failure of your cooling unit (not covered by warranty).

    BTU/h Rating

    3354

    The BTU/h value shown here is a theoretical number. There are often circumstances under which a cellar design may require a larger unit due to variables not accounted for in the formula. For example, these variables could be building materials (such as glass, stone, concrete, etc.) which do not offer the insulation capacity required to maintain the optimal cellar environment. We recommend purchasing a unit with a larger capacity to compensate for these unaccounted-for variables. An undersized unit can lead to premature failure and will most likely prevent the cellar from reaching your desired temperature.  

    Features

    • Now with energy-efficient EC Fans on both the cold and hot sides, save $300.77 in annual energy costs vs AC fans (assumes 75% runtime and $0.15/kWh)
    • CellarPro Air Handlers are engineered to be ducted with 8-inch insulated ducting on the cold side (evaporator) and/or 8-inch ducting on the hot side (condensing unit), allowing the equipment can be located out-of-sight where it won’t be heard.
    • Split systems are designed to separate the evaporator from the condensing unit up to 100 feet.
    • High-output EC fans provide more airflow and variable speed settings for your choice of cooling power.
    • Optional integrated humidifier provides the ultimate control of moisture levels inside your cellar.
    • Optional integrated heater provides heat for wine cellars that are exposed to temperatures below 55F.
    • Extra-large coils generate maximum cooling power inside the cellar.
    • Excess condensate is managed through a 1/2″ drain line that exits from a choice of knockouts in the evaporator.
    • Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
    • Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade.
    • Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
    • Temperature set point range is 47F to 62F when the cooling unit is properly sized.
    • Unit operates with minimal vibrations and less noise than comparable units from competitors.
    • Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
    • Remote probe for the cellar (bottle probe), air filter and duct adapters are included as standard equipment, and multiple knockouts and access points ensure easy installation.
    • Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range.
    • Removable steel case and refrigerant access valve provides access to the internal components for servicing and repair.
    • Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance.
    • Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet.
    • Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high.
    • Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation.
    • CellarPro’s 2-Year/5-Year Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
    • An optional Extended Warranty (P/N 31489) is available for additional protection.
    • ETL Tested and Certified to rigorous UL Standards for safety.

    Configurations

    • CellarPro AH3500Si-ECX units are designed to be ducted, with the evaporator near (or inside) the cellar, and the condensing unit in a remote interior location up to 100 feet away.
    • The evaporator and the condensing unit each can be ducted up to 100 Equivalent Feet (50 Feet per Duct) with 8-inch ducting .
    • CellarPro’s split configuration allows multiple ducting alternatives, as follows.
      • Collars or grills for EXHAUST (ie Supply) are located at the front (shown at left), top or rear of the cooling system, and are interchangeable to meet your specific requirement.
      • Collars or grills for INTAKE (ie Return) are located at each end (left: evaporator, and right: condenser), and include professional-grade air filters to protect the unit.
    • We recommend pulling the fresh air intake (hot-side) from a temperature-controlled environment (must be outside the cellar). If the hot-side exhaust will be directed to a different space than the intake, always make sure that both spaces are sufficiently voluminous so that you don’t run into issues with negative pressure.
    • A bottle probe temperature sensor (10′ cord) plus your choice of duct collars, indoor grills and blank plates are included in the price of the cooling system.
    • CellarPro Air Handler Split systems offer a choice of 110V / 60Hz wiring and power configurations:
      • Two permanent power connections for the evaporator (2.0 amps / 15 amp circuit breaker) and the condensing unit (8.7 amps / 15 amp circuit breaker). This wiring configuration is recommended for Valve Control.
      • One permanent power connection for the entire system (15 amp circuit breaker). In this configuration, the condensing unit must be wired to the evaporator, and must be used with Electronic Control.
      • The amp data above is not valid when the integrated heater and/or humidifier are configured with the cooling unit – please consult those Owner’s Manuals for the additional amps required when using those upgrades.
    • When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
    • The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space.
    • For installations in environments below 40F, AH3500Si-ECX units require our Compressor Heater (P/N 1727) (included).
    • For installation in environments below 20F down to -20F , Electronic Control is the required configuration, and our Fan-Cycling Switch (P/N 6972) is required in addition to the compressor heater (both sold separately).
    • The evaporator should never be exposed to temperatures below 32F.
    • Access to the left and right side of the evaporator unit is required for installation.
    • All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chart for more information.
    • A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.
    • We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge.
    • To activate your warranty, you must complete and return our Installation Checklist.
    Air Handler Series Configuration Options
    Click Here

    Specifications

    Cellar Size:Approx. 900 cu. ft. when cellar is fully insulated and sealed with a proper vapor barrier (each wine cellar is unique and has specific cooling requirements; heat load calculations should always be performed prior to selecting a cooling unit)
    BTU/h w/55°F:3354
    Evap Dimensions:18 5/8"W x 18 5/8"D x 19 1/4"H
    Condenser Dimensions:18.6"W x 18.6"D x 19.3"H
    Voltage Rating:110V / 60 Hz
    Weight:220 lbs
    Amps:9.0 (running amps)
    Ducting:8" Diameter

    Options & Upgrades

    Cold Temperature

    Compressor Heater #35605: protects the unit when installed in environments that drop below 40F down to 20F. Included
    Fan Cycling Switch #6972: supports the unit in temperatures below 20F and as low as -20F when configured with Electronic Control and combined with our compressor heater.


    Filters & Grills

    Use our filter & grill guide to find the cooling unit filter or duct filter and/or duct grill that is appropriate for your cooling unit.

    Maintenance

    Refer to filter replacements in the previous section.
    Evap Fresh #17984: Should be sprayed on the evaporator (cold-side) coils once a quarter, especially when the evaporator coils frequently have condensation, to extend the life of the evaporator coils and to reduce the growth of mold in the drain pan.
    Condenser Brush #1475: With a long handle and stiff bristles, the brush is ideal for cleaning off the dust and dirt that collect on the hot-side condenser coils, especially when a filter isn’t used on the coils.

    Remote Thermostats, Displays & Probes

    Networkable Thermostats #27346 and #27310: connect your cooling unit to a networkable, wi-fi enabled thermostat (sold separately). Must be ordered at the same time that the equipment is ordered. Other limitations apply – read the networkable thermostat description for more information. Includes 10 feet of wiring.
    Remote Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring. Additional wiring is available at a cost of $0.50 per additional foot.
    Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the cooling unit, and allows it to monitor air or liquid temperatures at various locations inside the cellar – included.
    Bottle probe extension cords are available in 25-foot (#1780) and 50-foot (#1781) lengths.

    Heating & Humidification

    Integrated Heater 900W #7237: adds 900 watts of heat through the cooling system when the cellar is in an unheated environment and will be exposed to temperatures below desired wine storage temperatures.
    Integrated Humidifier #36521: provides humidification with digital control inside the cellar when attached to an external water line.

    DID YOU KNOW?
    Nobody protects your wine cellar better than CellarPro Cooling Systems! In the event your cooling unit fails and the failed components are covered by our warranty, we’ll send a replacement cooling unit to you per the terms of our Replacement Unit Program

    CellarPro Replacement Unit Program
    If your CellarPro cooling unit fails and the parts that failed are still covered by warranty, we’ll send a replacement cooling unit to you, as follows:

    Your cooling unit must be registered at CellarPro
    Your cooling unit must have been properly sized, installed and maintained
    Your cooling unit may not have been permanently modified, damaged or disfigured

    Please note:

    Replacement units are factory-refurbished cooling units with a similar build date as your original unit
    You are responsible for the shipping cost to send the replacement unit to you and return the original unit to us, and the cost (if any) to remove the original unit and install the replacement unit
    In order to send a replacement unit, we require a deposit, which will be refunded minus shipping costs upon the return and pending the inspection of the original unit
    If the original unit failed due to improper intallation or use, the failure is not covered by warranty and we will deduct the cost of the repairs from the refund of your deposit

    Reviews

    There are no reviews yet.

    Be the first to review “CellarPro Ducted Air Handler Split 1/3 Ton AH3500Si”